Respiratory Protective Device–Testing and Certification
Respiratory Protective Device – Testing and Certification
& Ecosafene have rich experience to provide Testing and Certification service to PPE for Respiratory
Ä Respiratory Protective Device ( Respirator):
> Respiratory Protective Devices – full mask, half mask
> Respiratory Protective Devices - Gas
> Respiratory Protective Devices - Dust
Ä Respiratory Protective Device – Testing and Certification:
Ä CE marking to Respiratory Protective Device – Standard list:
Respiratory protective device is involved in PPE, it also MUST be apply CE Marking, otherwise the product will be blocked to European marked, and the product MUST comply with Personal Protective Equipment Directive (89/686/EEC)
Standard No.
|
Standard Name
|
EN 132:1998
|
Respiratory protective devices - Definitions of terms and pictograms
|
EN 133:2001
|
Respiratory protective devices – Classification
|
EN 134:1998
|
Respiratory protective devices - Nomenclature of components
|
EN 135:1998
|
Respiratory protective devices - List of equivalent terms
|
EN 136:1998
|
Respiratory protective devices - Full face masks - Requirements, testing, marking
|
EN 137:2006
|
Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with full face mask - Requirements, testing, marking
|
EN 138:1994
|
Respiratory protective devices - Fresh air hose breathing apparatus for use with full face mask, half mask or mouthpiece assembly - Requirements, testing, marking
|
EN 140:1998
|
Respiratory protective devices - Half masks and quarter masks - Requirements, testing, marking
|
EN 142:2002
|
Respiratory protective devices - Mouthpiece assemblies - Requirements, testing, marking
|
EN 143:2000
|
Respiratory protective devices - Particle filters - Requirements, testing, marking
|
EN 144-1:2000
|
Respiratory protective devices - Gas cylinder valves - Part 1: Thread connections for insert connector
|
EN 144-2:1998
|
Respiratory protective devices - Gas cylinder valves - Part 2: Outlet connections
|
EN 144-3:2003
|
Respiratory protective devices - Gas cylinder valves - Part 3: Outlet connections for diving gases Nitrox and oxygen
|
EN 145:1997
|
Respiratory protective devices - Self-contained closed-circuit breathing apparatus compressed oxygen or compressed oxygen-nitrogen type - Requirements, testing, marking
|
EN 148-1:1999
|
Respiratory protective devices - Threads for facepieces - Part 1: Standard thread connection
|
EN 148-2:1999
|
Respiratory protective devices - Threads for facepieces - Part 2: Centre thread connection
|
EN 149:2001
|
Respiratory protective devices - Filtering half masks to protect against particles - Requirements, testing, marking
|
EN 250:2000
|
Respiratory equipment - Open-circuit self-contained compressed air diving apparatus - Requirements, testing, marking
|
EN 269:1994
|
Respiratory protective devices - Powered fresh air hose breathing apparatus incorporating a hood - Requirements, testing, marking
|
EN 1146:2005
|
Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus incorporating a hood for escape - Requirements, testing, marking
|
EN 1827:1999
|
Respiratory protective devices - Half masks without inhalation valves and with separable filters to protect against gases or gases and particles or particles only - Requirements, testing, marking
|
EN 12083:1998
|
Respiratory protective devices - Filters with breathing hoses, (Non-mask mounted filters) - Particle filters, gas filters, and combined filters - Requirements, testing, marking
|
EN 12941:1998
|
Respiratory protective devices - Powered filtering devices incorporating a helmet or a hood - Requirements, testing, marking
|
EN 12942:1998
|
Respiratory protective devices - Power assisted filtering devices incorporating full face masks, half masks or quarter masks - Requirements, testing, marking
|
EN 13274-1:2001
|
Respiratory protective devices - Methods of test - Part 1: Determination of inward leakage and total inward leakage
|
EN 13274-2:2001
|
Respiratory protective devices - Methods of test - Part 2: Practical performance tests
|
EN 13274-3:2001
|
Respiratory protective devices - Methods of test - Part 3: Determination of breathing resistance
|
EN 13274-4:2001
|
Respiratory protective devices - Methods of test - Part 4: Flame tests
|
EN 13274-8:2002
|
Respiratory protective devices - Methods of test - Part 8: Determination of dolomite dust clogging
|
EN 13794:2002
|
Respiratory protective devices - Self-contained closed-circuit breathing apparatus for escape - Requirements, testing, marking
|
EN 13949:2003
|
Respiratory equipment - Open-circuit self-contained diving apparatus for use with compressed Nitrox and oxygen - Requirements, testing, marking
|
EN 14143:2003
|
Respiratory equipment - Self-contained re-breathing diving apparatus
|
EN 14387:2004
|
Respiratory protective devices - Gas filter(s) and combined filter(s) - Requirements, testing, marking
|
EN 14435:2004
|
Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only - Requirements, testing, marking
|
EN 14529:2005
|
Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with half mask designed to include a positive pressure lung governed demand valve for escape purposes only
|
EN 14593-1:2005
|
Respiratory protective devices - Compressed air line breathing apparatus with demand valve - Part 1: Apparatus with a full face mask - Requirements, testing, marking
|
EN 14593-2:2005
|
Respiratory protective devices - Compressed air line breathing apparatus with demand valve - Part 2: Apparatus with a half mask at positive pressure - Requirements, testing, marking
|
EN 14594:2005
|
Respiratory protective devices - Continuous flow compressed air line breathing apparatus - Requirements, testing, marking
|
Ä Respiratory Protective Device – Testing and Certification – America Standard
1) 1910 Subpart I, Personal protective equipment
2) 1910.132, General requirements
3) 1910.134, Respiratory protection
Ä Respiratory Protective Device – Testing and Certification – Chinese Standard
Product
|
Standard
|
Respiratory Protective Device - Gas filtered
|
GB2890-1995
|
Respiratory Protective Device - Gas filtered Mask
|
GB2890-1995
|
Mask – dust protection
|
LD29-1992
|
----------------------------------------------------------------------------------------------------------------------