久久精品中出人妻一区二区_午夜视频网站亚洲国产_国产三级在线观看高清_天天看片2017亚洲欧美在线_日韩av无码不卡_亚洲国产高清免费不卡_精品午夜福利在线看_电影天堂青青青手机频_2020人妻中文字幕_影音先锋aⅴ男人资源先锋影院

NF P92-505 Fire Test to Building Material - Dripping test

Article


NF P92-505 Fire Test to Building Material - Dripping test
 
Ecosafene Products Service Co.,Ltd have rich experience to provide French Standard NF P92-505 fire test to Building Material
 
NF P92-505 Fire test to Building materials - Standard

NF P 92-505: Dripping test with electrical radiator, used for melting materials.
If for NF P 92-501 and NF P 92-503 testing, there melt drops off, with or without combustion phenomenon, should conduct the test NF P 92-505. Comprehensive assessment M classification.
 
NF P92-505 Fire test to Building materials - Standard Brief
 
NF P 92-505 combustion is used to test whether the produced materials can be ignited lint (asbestos gasket) of the droplet. If the fire reaction tests in other non-combustible material or material generated droplet could not be determined rapidly shrinking spread of flame, drip test should be conducted, according to test results will be material dropping into M1 ~ M4 rating.
 
NF P92-505 testing requirements: the sample is placed horizontally on the sample rack, the vertical distance of30mm at its office, horizontal level of a power of 500W electric radiators, heat the sample to impose a certain amount of radiation in the sample under 300mm vertical distance by placing a receiving tray, drip tray lighted place for lint (asbestos gasket), test 10min. The testing processes while observing the flame, and if the sample is ignited before the 5min electric radiators should be removed, have radiation after 5min. The combustion of the samples, smoke and other associated phenomena in record. If lint (Asbestos Gasket) is lit, then determine the grade for the M4.
 
NF P 92-505 Fire test to building material (M Rating)– Similar Standard

-  Fire Test to Building Material according to French Standard – M Rating (M0,M1,M2,M3,M4)
-  NF P 92-510: Determination of upper calorific potential
-  NF P 92-501: Safety against fire: Building materials – Reaction to fire tests. used for rigidmaterial or flexible materials thicker than 5mm
-  NF P 92-503: Safety against fire - Building materials -Reaction to fire tests - Electrical burner test used for flexible materials
-  NF P 92-504: Safety against fire - Building materials - Reaction to fire tests - Flame persistence test and speed of the spread of flame.
-  NF P 92-505: Safety against fire - Building materials - Reaction to fire tests - Test used for thermal melting materials - Dripping test.
-  NF P 92-506: Safety against fire - Building Material - Flooring
-  NF P92-507: Fire safety - Building - Interior fitting materials - Classification according to their reaction to fire
----------------------------------------------------------------------------------------------------------------------